It is easier than you would
imagine.
1. Clean out the cavity.
2. Insert the aluminum-wrapped plywood spacer against best
concrete slab edge.
If both slab edges need repair,
aluminum-wrapped plywood spacer may be placed in middle of joint and
Con-Patch applied on both sides.
3. Mix and place Con-Patch.
4. Smooth out Con-Patch as pictured.
5. Pull out plywood and remove as much aluminum foil as possible
from the cavity.
Optional...
Install Flexible Joint Compound to prevent a cavity from
becoming imbedded with soil—traffic rolling over trapped metal pieces is a major contributor to
chipped slab edges. |