Technical Data
Con-Patch for Refrigerator or Freezer
Products No.
8145-0503 and No. 8145-0506 MSDS
Con-Patch is a three-component 100% solids epoxy mortar designed
for applications where temperatures are below freezing or a rapidly setting
patch is necessary.
Con-Patch is recommended for use in cold storage areas,
freezers, walkways, and support bases for tanks and seamless floors.
Not recommended for immersion applications for active
solvents.
Solids by Weight: 100%
Volatile Organic Content: Zero (0) Lbs. per gallon
Standard Color
Natural...
Other colors available on special order.
Recommended Thickness
⅛” to
¼"... Yet, works well from a feather to as thick as needed.
Coverage
No. 8145-0503... 5.145 sq. ft. @ ¼" and 10.29 sq. ft. @ ⅛"
No. 8145-0506... 20.58 sq. ft. @
¼"
and 41.17 sq. ft.
@ ⅛"
Packaging Cubic Feet
8145-0503 .11 (approx)
8145-0506 .43 (approx)
Content Weights
No. 8145-0503 No. 8145-0506
Part A = 1.56 Lbs. Part A = 6.25 Lbs.
Part B = .575 Lbs. Part B = 2.3 Lbs.
Aggregate = 12.5 Lbs. Aggregate = 50 Lbs
Shelf Life: 2 years in unopened containers
Abrasion Resistance: Excellent
DOT Classifications
Parts A & Aggregate = Not Regulated
Part B = Corrosive Liquid N.O.S., 8, UN1760, PGIII
Flexural Strength
10,350 psi @ ASTM D790
Compressive Strength
7,560 psi @ ASTM D695
Tensile Strength
6,030 psi @ ASTM D638
Ultimate Elongation: 7.3%
Impact Resistance: Excellent
Heat Deflection Temperature
113°F @ ASTM D648
Weathering
Good (chalks)
Cure Schedule at 70°F
Pot life – (.45 cu. ft. mix) ……. 10-15 minutes
Recoat or topcoat.....…...........……. 3-4 hours
Light foot traffic...………....…...........6-8 hours
Full cure (heavy traffic)... ………..…. 2-7 days
- Foot traffic serviceable....... 24 Hrs. @ 30°F
Application Temperature: 30°F to 80°F
Chemical Resistance
Reagent Rating
xylene........... C
1,1,1 trichlorethane............ C
MEK.......... A
Methanol........... A
ethyl alcohol............ C
skydrol........... B
10% sodium hydroxide............ D
50% sodium hydroxide............ C
10% sulfuric acid........... C
70% sulfuric acid........... A
10% HC1 (aq)........... C
5% acetic acid..........
B
Rating Key
A = Not recommended
B = 2 hour term splash spill
C = 8 hour term splash spill
D = 72 hour immersion
E = Long term immersion
NOTE: extensive chemical resistance information is available
upon request.
Primer:
None required but we suggest applying mixed liquid to area being
patched prior to mixing in aggregate. If there is a sizeable amount of
area to be patched or capped, you may wish to prime the surfaces to which the
patch is to be applied with Gabriel Conset Primer.
Top Coat:
Not
required but top coatings do bond well.
Product
Limitations
1. Color stability may be affected by environmental conditions such as high
humidity or chemical exposure.
2. Product is not UV color stable and may discolor if exposed to lighting such
as sodium vapor lights.
3. Colors may vary from batch to batch due to variations in the silica filler.
4. Mortar colors are not from our standard color chart.
5. Substrate temperatures must be 5°F above dew point.
6. For chemical exposure areas, we recommend a suitable topcoat to reduce
porosity and chemical migration.
7. New concrete must set at least 30 days before applying Con-Patch.
8. Test data based on neat resin.
9. Physical properties are typical values and not specifications.
10.
This
product has a short pot life, mix only an amount of material that can be used in
the prescribed pot life period.
11. When temperatures are low, extended time may be required for the material to
cure before allowing industrial traffic.
12. Product quality guaranteed for 60 days from date of sale...
We offer no written or implied warranty as
to the results of your work on the job(s) for which this product was used.
Important Information
1. Product Storage:
Store product in an area so as to bring the material to normal room temperature
before using. Continuous storage should be above 55°F
to prevent
product crystallization.
2. Surface Preparation: All dirt, oil, dust, foreign contaminants and laitance must be removed to assure a trouble free bond to the substrate. We recommend that an aggressive shot blast be performed prior to the application of this product. A less adequate method would be acid etching, but the etch should properly profile the substrate. All edges and around columns or beams should be mechanically scarified. All termination points should not be feather edged, but should be saw cut with the termination ending at the saw cut. All large cracks should be V cut and filled with appropriate crack filler. All expansion joints should be filled with an appropriate joint filler. When overlaying an expansion joint, a single saw cut through the epoxy overlay will prevent random fracturing. A test should be made to determine that the concrete is dry; this can be done by placing a 4'x4' plastic sheet on the substrate and taping down the edges. If after 24 hours, the substrate is still dry below the plastic sheet, then the substrate is dry enough to start coating. The plastic sheet testing is also a good method to determine if any hydrostatic pressure problems exist that may later cause bonding problems.
3. Primer: No primer is necessary. This material is self priming. However, any suitable primer may be used.
4. Product Mixing: It is important that the liquids be mixed together first. Mix the liquids in an oversized container thoroughly and until streak free. After the liquids are thoroughly mixed, add in the aggregate. Mix in the aggregate with slow speed mixing equipment such as a jiffy mixer or rotating bucket/stationary mixing blade assembly. It is equally important that enough time is spent mixing in the aggregate to insure that the aggregate is thoroughly wetted out. No induction time is necessary. Improper mixing may result in product failure.
5. Product Application: Apply the mixed material at ⅛” to ¼" thickness. Apply the material with a hand trowel or other suitable application equipment. Do not over-trowel the material as this may cause isolated blisters to form. Direct air currents above or across the mortar during the curing process may cause isolated blisters to form. Maintain temperatures within the recommended ranges during the application and curing process.
6. Recoat or Top Coat: No recoating or top coating is necessary. However, if you opt to topcoat the applied mortar, allow it to cure before top coating. Many epoxies and urethanes can be used. Contact Gabriel Technical Support for suitable topcoat selections.
7. Cleanup: Use xylol
8. Floor Cleaning:
Caution! Some cleaners may affect the color of the floor installed. Test each
cleaner in a small area, utilizing your cleaning technique. If no ill effects
are noted, you may continue to clean with the product and process tested.
9. Restrictions:
Restrict the use of the floor to light traffic and non-harsh chemicals until the
coating is fully cured (see technical data under full cure). It is best to let
the floor remain dry for the full cure cycle.
NOTICE TO BUYER: DISCLAIMER OF WARRANTIES AND LIMITATIONS ON OUR LIABILITY
We warrant that our products are manufactured to strict quality assurance specifications and that the information supplied by us is accurate to the best of our knowledge. Such information supplied about our products is not a representation or a warranty. It is supplied on the condition that you shall make your own tests to determine the suitability of our product for your particular purpose. Listed physical properties are typical and should not be construed as specifications. NO WARRANTY IS MADE, EXPRESSED OR IMPLIED, REGARDING SUCH OTHER INFORMATION, THE DATA ON WHICH IT IS BASED, OR THE RESULTS YOU WILL OBTAIN FROM ITS USE. N0 WARRANTY IS MADE, EXPRESSED OR IMPLIED, THAT OUR PRODUCT SHALL BE MERCHANTABLE OR THAT OUR PRODUCT SHALL BE FIT FOR ANY PARTICULAR PURPOSE. NO WARRANTY IS MADE THAT THE USE OF SUCH INFORMATION OR OUR PRODUCT WILL NOT INFRINGE UPON ANY PATENT. We shall have no liability for incidental or consequential damages, direct or indirect. Our liability is limited to the net selling price of our product or the replacement of our product, at our option. Acceptance of delivery of our product means that you have accepted the terms of this warranty whether or not purchase orders or other documents state terms that vary from this warranty. No representative is authorized to make any representation or warranty or assume any other liability on our behalf with any sale of our products. Our products contain chemicals that may CAUSE SERIOUS PHYSICAL INJURY. BEFORE USING, READ THE MATERIAL SAFETY DATA SHEET AND FOLLOW ALL PRECAUTIONS TO PREVENT BODILY HARM.
MSDS
© 2005 Gabriel First Corp.