Enzyme Spot Cleaner

Item Number: 8577-1703

 

U.S. Department Of Labor

Occupational Safety And Health Administration

MATERIAL SAFETY DATA SHEET

Required Under USDL Safety And Health Regulations

(29 CFP 1910.1200 "Hazards Communication Standard")

 

Section I

Manufactured For:  Gabriel First Corp.

Emergency Telephone:  1-800-424-9300

Address:  233 W Commercial Street  East Rochester, NY   14445

Trade Name & Synonyms: Enzyme Spot Cleaner

Chemical Family: Carpet Spot Remover

Prepared On:  08/12/2010

HMIS RATING

                                        HEALTH                        FLAMMABILITY                   REACTIVITY                              MPP

                                               1                                              0                                              0                                              B

 

Section II - Product & Component Data

Chemical Names                                                     CAS                %                                       TLV

Water                                                                     7732-18-5           To 86                                    N/E

Natural Enzyme                                                        N/E                  To 10                                   N/E

Nonionic Surfactant Blend                                Mixture               To 1                                      N/E

Fragrance                                                            Proprietary          To 0.5                                   None

 

Section III - Physical Data

Boiling Point: 212°F - 220°F

Specific Gravity (H2O=1): 1.01

Vapor Pressure: ND

Percent, Volatile By Volume(%): 92-94

Vapor Density(Air=1):  Same as Water

Evaporation Rate: N/A

Solubility In Water: Complete.

Appearance And Odor: Milky Liquid, Pleasant odor.

pH: 6-7

 

Section IV - Fire And Explosion Hazard Data

Special Fire Fighting Procedures: N/A

Flash Point:  Exceeds 200°F

Flammable Limits: Non-Flammable

Extinguishing Media: Water, CO2

Unusual Fire And Explosion Hazards: None

 

Section V - Health Hazard Data

Eyes:  May cause irritation.

Skin: May cause irritation.

Inhalation: May cause irritation to upper tract.

Ingestion: May cause irritation of mucous membranes.

Medical Conditions Aggravated By Exposure:  Person with present skin disorder may be more susceptible to irrritation.

Emergency First Aid Procedures:

Eyes: Flush with running water for 15 minutes.

Skin: Wash with soap and water. 

Ingestion: Do not induce vomiting.  Drink plenty of water.  If unconscious or in convulsion, take to hospital or physician.

Inhalation:  Remove to fresh air.

 

Section VI - Reactivity Data

Stability:  Stable

Incompatibility - Materials To Avoid: None

Hazardous Decomposition Products: Normal products of combustion.

Hazardous polymerization:  Will not occur.

 

Section VII - Spill Or Leak Procedures

Steps To Be Taken In Case Material Is Released Or Spilled: Mop and absorb for disposal.

Waste Disposal Method: Dispose of in sewer or incinerate with local approval.

 

Section VIII - Special Protection Information

Respiratory Protection: No special requirements.

Ventilation:  Good ventilation required..

Protective Gloves: Rubber.

Eye Contact: Goggles or face shield. 

Section IX - Special Precautions

Deep out of reach of children.  Use only in well-ventilated area.  For institutional and industrial use only.  For use by trained personnel only.  Store and keep in closed container, in a cool place.  Avoid Freezing.

 

                                                                                                                           Section X - Spills or Leaks
SPILLAGE:  Dike and contain spill, absorb the liquid.

DISPOSAL:  Scoop or shovel solid material into a suitable container for recovery or disposal.  Area may become slippery.  Flush cleaned area with water.  Dispose according to local, state, and federal requirements.

 

 

 

 

This information is given in good faith, but no warranty expressed or implied is made. Our company believes that it is accurate to the best of its knowledge and relates only to the specific material designated herein.